1.
PLoS One ; 16(1): e0245305, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33449952

RESUMO

PURPOSE: To evaluate the performance of eleven Knowledge-Based (KB) models for planning optimization (RapidPlantm (RP), Varian) of Volumetric Modulated Arc Therapy (VMAT) applied to whole breast comprehensive of nodal stations, internal mammary and/or supraclavicular regions. METHODS AND MATERIALS: Six RP models have been generated and trained based on 120 VMAT plans data set with different criteria. Two extra-structures were delineated: a PTV for the optimization and a ring structure. Five more models, twins of the previous models, have been created without the need of these structures. RESULTS: All models were successfully validated on an independent cohort of 40 patients, 30 from the same institute that provided the training patients and 10 from an additional institute, with the resulting plans being of equal or better quality compared with the clinical plans. The internal validation shows that the models reduce the heart maximum dose of about 2 Gy, the mean dose of about 1 Gy and the V20Gy of 1.5 Gy on average. Model R and L together with model B without optimization structures ensured the best outcomes in the 20% of the values compared to other models. The external validation observed an average improvement of at least 16% for the V5Gy of lungs in RP plans. The mean heart dose and for the V20Gy for lung IPSI were almost halved. The models reduce the maximum dose for the spinal canal of more than 2 Gy on average. CONCLUSIONS: All KB models allow a homogeneous plan quality and some dosimetric gains, as we saw in both internal and external validation. Sub-KB models, developed by splitting right and left breast cases or including only whole breast with locoregional lymph nodes, have shown good performances, comparable but slightly worse than the general model. Finally, models generated without the optimization structures, performed better than the original ones.


Assuntos
Neoplasias da Mama/radioterapia , Linfonodos/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Feminino , Humanos , Linfonodos/patologia , Glândulas Mamárias Humanas/efeitos da radiação , Mediastino/efeitos da radiação , Órgãos em Risco , Radiação Ionizante , Dosagem Radioterapêutica , Radioterapia Adjuvante , Estudos Retrospectivos
2.
Radiat Oncol ; 15(1): 150, 2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-32532351

RESUMO

PURPOSE: Retrospective analysis of volumetric modulated arc therapy treatment plans to investigate qualitative, possible, clinical consequences of the use of AAA versus AXB in nasopharyngeal cancer (NPC) cases. METHODS: The dose distribution of 26 treatment plans, produced using RapidArc technique and AAA algorithm, were recalculated using AXB and the same number of monitor units provided by AAA and clinically delivered to each patient. The potential clinical effect of dosimetric differences in the planning target volume (PTV) and in organs at risk (OAR) were evaluated by comparing TCP and NTCP values. The Wilcoxon Signed Rank test was used for statistical comparison of all results obtained from the use of the two algorithms. RESULTS: The poorer coverage of the PTV, with higher prescribed dose, was reflected in the TCP, which was significantly lower when AXB was used, the median value was 81.55% (range: 74.90, 88.60%) and 84.10% (range: 77.70, 89.90%) for AAA (p < 0.001). OAR mean dose was lower in the AXB recalculated plan than the AAA plan and the difference was statistically significant for all the structures. The NTCP for developing mandible necrosis showed the largest median percentage difference between AAA and AXB (56.6%), the NTCP of risk for larynx edema of Grade ≥ 2 followed with 12.2%. CONCLUSIONS: Differences in dose distribution of NPC treatment plans recalculated with AXB are of clinical significance in those situations where the PTV and OAR involve air or bone, media in which AXB has been shown to more accurately represent the true dose distribution. The availability of AXB algorithm could improve patient dose estimation, increasing the data consistency of clinical trials.


Assuntos
Algoritmos , Carcinoma Nasofaríngeo/radioterapia , Neoplasias Nasofaríngeas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos